News & Events |
 |
|
| |
|
ESL SIGNS WITH LLOYD'S REGISTER FOR CERTIFICATION OF THEIR MANAGEMENT SYSTEM
ESL has signed an agreement with Lloyd's Register Quality Assurance Ltd having its registered... More |
| |
|
|
COCA COLA CHOOSES AKSA FOR ITS LAHORE PLANT
Coca Cola has placed an order for 2x2250 kVA Aksa gensets with Cummins QSK60G4... More |
 |
 |
|
PICTL PLACES AN ORDER FOR ANOTHER 11KV, 1675KVA AKSA GEN-SET
Pakistan International Container Terminal Limited (PICTL) has once again shown confidence... More |
 |
 |
|
ORIX LEASING MAKES AKSA THE BRAND OF CHOICE
The contents of Aksa sets in Orix rental fleet has increased to almost 25%... More |
| |
 |
|
ESL HAS MOVED TO NEW PREMISES
ESL has moved to new premises which is completely.... More |
| |
 |
|
MOBILINK SIGNS CONTRACT WITH ESL
Pakistan Mobile Corporation Limited has signed the following two contracts with ESL... More |
| |
|
|
ESL WINS SHELL TENDER FOR THE MID REGION
ESL participated in online tender from Shell Pakistan for supply of spares and services and won the... More |
| |
|
|
ESL WINS UET TENDER FOR SALES, SERVICE, INSTALLATION & COMMISSIONING OF GAS SETS
ESL participated in tender from UET and won the following... More |
| |
|
|
|
|
|
|
|
|
 |
 |
|
|
ALP 8 |
 |
|
| 400 / 230 V V - 50 Hz |
Generating Set Model |
ALP 8 |
Power
Pf. 0,8 |
Standby kVA |
8,5 |
| Prime kVA |
7,5 |
Standby:Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. In accordance with ISO 3046, BS 5514. |
Prime:Continuous running at variable load for unlimited periods with 10% overload avilable for 1 hour in any 12 hours period. In accordance ISO 8528, ISO 3046. Contact us for the other running periods. |
DESIGN SPECIFICATIONS
- High quality, reliable and complete power unit
- Compact design
- Easy start and maintenance possibility
- Every generating set is subjected to a comprehensive test programme which includes full load testing and checking and providing of all control and safety shut down functions testing.
- Full engineered with a wide range of options and acessories: Canopy, soundproof canopy, and on road trailer
|
| |
STANDARD GENSET SPECIFICATIONS |
|
ENGINE: |
- <b>LISTER PETTER</b> diesel engine
- Four cycle, water cooled,
- Direct injection fuel system.
- Mechanical Governer Control System.
- 12 Volt D.C. starter and charge alternator
- Replaceable fuel filter
- Cooling radiator and fan
- Flexible fuel connection hoses and sump oil drain valve
- Industrial capacity exhaust silencer and expansion joint
- Starter battery ( with lead acid) including Rack and Cables
- Jacket water heater ( at automatic models)
- Operation manuals and circuit diagrams documents
|
ALTERNATOR: |
- Brushless, single bearing system, 4 poles
- Insulation class H
- Standard degree of protection IP23
- Self-exciting and self-regulating
- Solid State Automatic voltage regulator
- Vacuum-impregnated windings with epoxy varnish
- Stator winding with 2/3 pitch for improved harmonics.
|
CHASSIS: |
- Steel chassis and antivibration pads
- Base frame design incorporates an integral fuel tank
- The generating set can be lifted or carefully pushed/pulled by the base frame
- Dial type fuel gauge and drain plug on the fuel tank.
- Forklift pockets within base frame.
|
CANOPY: |
- All canopy parts are designed with modular principles
- Without welding assembly
- All metal canopy parts are painted by electrostatic polyester powder paint
- Exhaust silencer manufactured from aluminium plated steel.
- Emergency stop push button is installed outside of canopy
- Modular canopy can also be installed at a later date.
- Easy maintenance and operation
- Easy lifting and moving
- Thermally insulated engine exhaust system.
|
QUALITY STANDARDS: |
- The equipment meets the following standards: IEC 34-1, ISO 3046, VDE 0530, BS 4999, BS 5000. The generating set is manufactured by a full accredited NQA-ISO 9001.
|
WARRANTY: |
- 12 months warranty from commissioning date as standard.
|
CONTROL SYSTEM: |
- Control, supervision and protection panel is mounted on the genset base frame. The control panel is equipped as follows;
- 1. Auto. Mains Failure Control Panel – P300
- Control Panel equipments:
- Control with DSE 720 module
- Static battery charger
- Emergency stop push button
-
- a) Generating Set Control Module DSE 720 Features:
- The module is used to monitor a mins supple and automatically start a standby generator set.
- Scrolling digital LCD display
- Front panel configuration of timers and alarm trip points
- Easy push button control
- OFF-MANUAL-AUTO-TEST-START
- LCD display Scroll push button.
- b) Metering, via LCD display:
- Generator Volt (F-N)
- Generator Ampere (L1, L2, L3)
- Generator Frequency (Hz)
- Mains Volts (F-F / F-N)
- Engine Temperature
- Engine Oil pressure
- Engine Speed
- Engine Hours run
- Plant battery volt
- c) Alarms, via LCD Display
- Over Current
- Over Speed
- Under / Over mains volt
- Under / Over mains frequency
- Low oil pressure
- High engine temperature
- Low battery volt
- Charge fail
- Start failure
- Emergency stop
- d) Led Indications
- Mains available
- Mains on load
- Generator available
- Generator on load
|
|
|
Diesel Generating Sets 400 / 230 V V - 50 Hz |
G
R
O
U
P |
MODEL |
ALP 8 |
Power
Pf. 0,8 |
|
|
8,5
6,8 |
|
|
7,5
6 |
D
I
E
S
E
L
E
N
G
I
N
E |
Engine Make |
Lister Petter |
Model |
LPW 2 |
Gross engine power output at rated rpm |
kWm
hp |
8.2
11 |
Aspiration and Cooling |
Natural Aspiration |
Cylinders Capacity |
Lt |
0.93 |
Cylinders and Build |
2 In line |
Engine Speed |
rpm |
1500 |
Bore and Stroke |
mmxmm |
86x80 |
Compression Ratio |
18.5:1 |
Governor |
Mechanical |
Fuel Consumption |
Load
L/hr |
|
Fuel Tank Capacity |
Lt |
80 |
Oil Capacity |
Lt |
3.2 |
Water Capacity |
Lt |
5.5 |
Air Intake - Engine |
m³/min |
9.87 |
Exhaust Gas Flow |
m³/min |
27 |
Alternator Voltage Regulation |
± %1,5 |
OPEN TYPES |
Dimensions (length x width x height) |
mm |
1380x770x980 |
Dry weight |
kg |
365 |
SOUND ATTENUATED TYPE |
Canopy Model |
|
ASM 1 |
Dimensions (length x width x height) |
mm |
1770x820x1180 |
Dry weight |
kg |
510 |
* Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice. |
OPTIONAL EQUIPMENTS |
| * Diesel Engine |
* |
| * Low coolant level |
* Remote radiator |
| * Oil heater |
* |
| * Alternator |
* |
| * 3 pole outlet circuit breaker |
* Oversized alternator |
| * Anti-condensation heater |
* |
| * Panel |
* |
| * Charge ammeter |
* Transfer switch 3 pole |
| * Transfer switch 4 pole |
* Earth fault, single set |
| * Accessories |
* |
| * Bulk fule tank |
* Automatic fuel filling system |
| * Fuel water separator filter |
* Manuel fuel filling system |
| * Low fuel level alarm |
* Residential silencer |
| * Enclosure canopy |
* Sound proof canopy |
| * Trailer |
* Manuel oil drain pump. |
| * Tool kit for maintenance |
|
|
|
|
|
|