Home
 
About ESL
 
AKSA
 
Why Customer Chooses AKSA/ESL?
 
Management Team
 
ESL Rentals
 
ESL Services
 
ESL Projects
 
ESL Portables
 
ESL Customers
 
Careers
 
Online Inquiry
 
Contact Us
 
Special Offer for Corporate Clients
 
Reime NIS
 
Company Profile
 News & Events
 
ESL SIGNS WITH LLOYD'S REGISTER FOR CERTIFICATION OF THEIR MANAGEMENT SYSTEM
ESL has signed an agreement with Lloyd's Register Quality Assurance Ltd having its registered... More
   
COCA COLA CHOOSES AKSA FOR ITS LAHORE PLANT
Coca Cola has placed an order for 2x2250 kVA Aksa gensets with Cummins QSK60G4... More
PICTL PLACES AN ORDER FOR ANOTHER 11KV, 1675KVA AKSA GEN-SET
Pakistan International Container Terminal Limited (PICTL) has once again shown confidence... More
ORIX LEASING MAKES AKSA THE BRAND OF CHOICE
The contents of Aksa sets in Orix rental fleet has increased to almost 25%... More
 
ESL HAS MOVED TO NEW PREMISES
ESL has moved to new premises which is completely.... More
 
MOBILINK SIGNS CONTRACT WITH ESL
Pakistan Mobile Corporation Limited has signed the following two contracts with ESL... More
   
ESL WINS SHELL TENDER FOR THE MID REGION
ESL participated in online tender from Shell Pakistan for supply of spares and services and won the... More
   
ESL WINS UET TENDER FOR SALES, SERVICE, INSTALLATION & COMMISSIONING OF GAS SETS
ESL participated in tender from UET and won the following... More
 
   
  View All
 
   ALP 12
400 / 230 V V - 50 Hz Generating Set Model ALP 12
Power
Pf. 0,8
Standby kVA 12
Prime kVA 11
Standby:Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. In accordance with ISO 3046, BS 5514.
Prime:Continuous running at variable load for unlimited periods with 10% overload avilable for 1 hour in any 12 hours period. In accordance ISO 8528, ISO 3046. Contact us for the other running periods.

DESIGN SPECIFICATIONS

  • High quality, reliable and complete power unit
  • Compact design
  • Easy start and maintenance possibility
  • Every generating set is subjected to a comprehensive test programme which includes full load testing and checking and providing of all control and safety shut down functions testing.
  • Full engineered with a wide range of options and acessories: Canopy, soundproof canopy, and on road trailer
STANDARD GENSET SPECIFICATIONS
ENGINE:
  • Four cycle, water cooled,
  • Direct injection fuel system.
  • Mechanical Governer Control System.
  • 12 Volt D.C. starter and charge alternator
  • Replaceable fuel filter
  • Cooling radiator and fan
  • Flexible fuel connection hoses and sump oil drain valve
  • Industrial capacity exhaust silencer and expansion joint
  • Starter battery ( with lead acid) including Rack and Cables
  • Jacket water heater ( at automatic models)
  • Operation manuals and circuit diagrams documents
ALTERNATOR:
  • Brushless, single bearing system, 4 poles
  • Insulation class H
  • Standard degree of protection IP23
  • Self-exciting and self-regulating
  • Solid State Automatic voltage regulator
  • Vacuum-impregnated windings with epoxy varnish
  • Stator winding with 2/3 pitch for improved harmonics
CHASSIS:
  • Steel chassis and antivibration pads
  • Base frame design incorporates an integral fuel tank
  • The generating set can be lifted or carefully pushed/pulled by the base frame
  • Dial type fuel gauge and drain plug on the fuel tank.
  • Forklift pockets within base frame.
CANOPY:
  • All canopy parts are designed with modular principles
  • Without welding assembly
  • All metal canopy parts are painted by electrostatic polyester powder paint
  • Exhaust silencer manufactured from aluminium plated steel.
  • Emergency stop push button is installed outside of canopy
  • Modular canopy can also be installed at a later date.
  • Easy maintenance and operation
  • Easy lifting and moving
  • Thermally insulated engine exhaust system.
QUALITY STANDARDS:
  • The equipment meets the following standards: IEC 34-1, ISO 3046, VDE 0530, BS 4999, BS 5000. The generating set is manufactured by a full accredited NQA-ISO 9001.
WARRANTY:
  • 12 months warranty from commissioning date as standard.
CONTROL SYSTEM:
  • Control, supervision and protection panel is mounted on the genset base frame. The control panel is equipped as follows;
  • 1. Auto. Mains Failure Control Panel – P300
  • Control Panel equipments:
  • Control with DSE 720 module
  • Static battery charger
  • Emergency stop push button
  • a) Generating Set Control Module DSE 720 Features:
  • The module is used to monitor a mins supple and automatically start a standby generator set.
  • Scrolling digital LCD display
  • Front panel configuration of timers and alarm trip points
  • Easy push button control
  • OFF-MANUAL-AUTO-TEST-START
  • LCD display Scroll push button.
  • b) Metering, via LCD display:
  • Generator Volt (F-N)
  • Generator Ampere (L1, L2, L3)
  • Generator Frequency (Hz)
  • Mains Volts (F-F / F-N)
  • Engine Temperature
  • Engine Oil pressure
  • Engine Speed
  • Engine Hours run
  • Plant battery volt
  • c) Alarms, via LCD Display
  • Over Current
  • Over Speed
  • Under / Over mains volt
  • Under / Over mains frequency
  • Low oil pressure
  • High engine temperature
  • Low battery volt
  • Charge fail
  • Start failure
  • Emergency stop
  • d) Led Indications
  • Mains available
  • Mains on load
  • Generator available
  • Generator on load
TECHNICAL DATA
Diesel Generating Sets 400 / 230 V V - 50 Hz
  G
  R
  O
  U
  P
MODEL ALP 12
Power
Pf. 0,8

12
10

11
8,8
  D
  I
  E
  S
  E
  L

  E
  N
  G
  I
  N
  E
Engine Make
Lister Petter
Model
LPW 3
Gross engine power output at rated rpm
kWm
hp
12.4
16.6
Aspiration and Cooling
Natural Aspiration
Cylinders Capacity
Lt
1.39
Cylinders and Build
3 In line
Engine Speed
rpm
1500
Bore and Stroke
mmxmm
86x80
Compression Ratio
18.5:1
Governor
Mechanical
Fuel Consumption
Load
L/hr
1/2 3/4 Full
1.6 2.2 2.8
Fuel Tank Capacity
Lt
90
Oil Capacity
Lt
4
Water Capacity
Lt
6.5
Air Intake - Engine
m³/min
14.81
Exhaust Gas Flow
m³/min
41.4
Alternator Voltage Regulation
± %1

OPEN TYPES
Dimensions (length x width x height)
mm
1450x820x1040
Dry weight
kg
440

SOUND ATTENUATED TYPE
Canopy Model
ASM 2
Dimensions (length x width x height)
mm
1920x870x1280
Dry weight
kg
605
* Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.

OPTIONAL EQUIPMENTS
* Diesel Engine
* Low coolant level
* Remote radiator
* Oil heater
*
* Alternator
* 3 pole outlet circuit breaker
* Oversized alternator
* Anti-condensation heater
*
* Panel
* Charge ammeter
* Transfer switch 3 pole
* Transfer switch 4 pole
* Earth fault, single set
*
* Accessories
* Bulk fule tank
* Automatic fuel filling system
* Fuel water separator filter
* Manuel fuel filling system
* Low fuel level alarm
* Residential silencer
* Enclosure canopy
* Sound proof canopy
* Trailer
* Manuel oil drain pump.
* Tool kit for maintenance
© 2008 All rights reserved by Energy Solutions (Pvt) Limited.