News & Events |
 |
|
| |
|
ESL SIGNS WITH LLOYD'S REGISTER FOR CERTIFICATION OF THEIR MANAGEMENT SYSTEM
ESL has signed an agreement with Lloyd's Register Quality Assurance Ltd having its registered... More |
| |
|
|
COCA COLA CHOOSES AKSA FOR ITS LAHORE PLANT
Coca Cola has placed an order for 2x2250 kVA Aksa gensets with Cummins QSK60G4... More |
 |
 |
|
PICTL PLACES AN ORDER FOR ANOTHER 11KV, 1675KVA AKSA GEN-SET
Pakistan International Container Terminal Limited (PICTL) has once again shown confidence... More |
 |
 |
|
ORIX LEASING MAKES AKSA THE BRAND OF CHOICE
The contents of Aksa sets in Orix rental fleet has increased to almost 25%... More |
| |
 |
|
ESL HAS MOVED TO NEW PREMISES
ESL has moved to new premises which is completely.... More |
| |
 |
|
MOBILINK SIGNS CONTRACT WITH ESL
Pakistan Mobile Corporation Limited has signed the following two contracts with ESL... More |
| |
|
|
ESL WINS SHELL TENDER FOR THE MID REGION
ESL participated in online tender from Shell Pakistan for supply of spares and services and won the... More |
| |
|
|
ESL WINS UET TENDER FOR SALES, SERVICE, INSTALLATION & COMMISSIONING OF GAS SETS
ESL participated in tender from UET and won the following... More |
| |
|
|
|
|
|
|
|
|
 |
 |
ADR 28 |
 |
| 400 / 230 V V - 50 Hz |
Generating Set Model |
ADR 28 |
Power
Pf. 0,8 |
Standby kVA |
27,5 |
| Prime kVA |
25 |
Standby:Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. |
Prime:Continuous running at variable load for unlimited periods with 10%. Overload available for 1 hour in any 12-hour period. |
DESIGN SPECIFICATIONS
- High quality, reliable and complete power unit
- Every generating set is subjected to a comprehensive test programme which includes full load testing and checking and providing of all control and safety shut down functions testing
- Full engineered with a wide range of options and accessories; both electrical and mechanical, soundproof canopy and on road trailer
- Compact design: ES series DG sets are smaller and lighter than any other DG set in it's class.
|
|
STANDARD GENSET SPECIFICATIONS |
|
ENGINE: |
- Cummins, X and S series, 1500 rpm, diesel engines.
- Four stroke, water cooled, direct injection fuel system.
- Mechanical Governor Control System
- Dual fuel filter
- Full flow lub oil filter
- Changeable cylinder liners
- Dry type air cleaner
- 12 V D.C. starter and charge alternator
- Cooling radiator
- Flexible fuel connection hoses
- Industrial capacity exhaust silencer
- Starter battery (with lead acid)
- Jacket water heater (at automatic models)
- Operation manuals and circuit diagrams documents
|
ALTERNATOR: |
- Stamford Alternator from Newage
- Screen protected and drip-proof, brushless type, revolving field, self-exciting, 4 poles, IP 23 Enclosure, single bearing system, self regulated through an automatic voltage regulator.
|
CHASSIS: |
- The complete generator set is mounted as whole on a heavy-duty fabricated, steel base frame. Antivibration pads are fixed between the engine/ alternator feet anf the base frame.
- Base frame design incorporates FRP fuel tank.
|
CANOPY: |
- Easy maintenance and operation are supplied by design.
- All metal canopy parts are painted by electrostatic powder paint.
- Emergency stop button is assembled on outside of canopy
|
QUALITY STANDARDS: |
- The equipment meets the following standards: BS 4999/5000, ISO 8528, VDE 0530, IEC34-1, ISO 3046, BS 5514.
|
WARRANTY: |
- 12 months warranty from commissioning date as standard.
|
CONTROL SYSTEM: |
- Control, supervision and protection panel is mounted on the genset base frame. The control panel is equipped as follows;
- 1) Auto Start and control panel
- The control panel is equipped as follows:
- Control with PCC 300 module
- Multi function meter
- Emergency Stop button
-
- a) Control Module PCC 300 Features:
- Generator Set, monitoring and control
- Microprocessor based design
- Generator set, manual and remote Start/Stop
- Shutdown fault indication and Start push button
- b) Protections and Indications:
- High engine temperature, shutdown.
- Low oil pressure, shutdown.
- Over speed.
- Fail to start
- Charge fail
- c) Multi Function Meter Which Measures:
- Generator phase Voltages (V)
- Generator Phase Current (A)
- Generator Phase Frequency (Hz)
- Engine water Temperature (°C)
- Engine lube oil Pressure (kg/cm2)
- 2) MCCB of Suitable Rating with Overload and Short Circuit
|
|
|
Diesel Generating Sets 400 / 230 V V - 50 Hz |
G
R
O
U
P |
MODEL |
ADR 28 |
Power
Pf. 0,8 |
|
|
27,5
22 |
|
|
25
20 |
D
I
E
S
E
L
E
N
G
I
N
E |
Engine Make |
Cummins |
Model |
X2.5G2 |
Gross engine power output at rated rpm |
kWm
hp |
23.8
32 |
Aspiration and Cooling |
Natural |
Cylinders Capacity |
Lt |
2.5 |
Cylinders and Build |
3-In line |
Engine Speed |
rpm |
1500 |
Bore and Stroke |
mmxmm |
91.4 x 127 |
Compression Ratio |
18.5:1 |
Governor |
Mechanical |
Fuel Consumption |
Load
L/hr |
|
Fuel Tank Capacity |
Lt |
45 |
Oil Capacity |
Lt |
6.5 |
Water Capacity |
Lt |
7.5 |
Air Intake - Engine |
m³/min |
|
Exhaust Gas Flow |
m³/min |
|
Alternator Voltage Regulation |
± %1.5 |
OPEN TYPES |
Dimensions (length x width x height) |
mm |
1400 x 730 x 1210 |
Dry weight |
kg |
490 |
SOUND ATTENUATED TYPE |
Canopy Model |
|
ASG 1 |
Dimensions (length x width x height) |
mm |
1900 x 810 x 1560 |
Dry weight |
kg |
790 |
* Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice. |
OPTIONAL EQUIPMENTS |
* Fuel - water separator filter |
* Automatic fuel filling system |
* Low fuel level alarm |
* Charge voltmeter |
* Charge ammeter |
* Auto Mains Failure & Transfer switch panel |
* Residential type silencer |
* Enclosure, soundproof canopy |
* Trailer |
* Remote Radiator |
* Manuel fuel Filling system |
* Charge voltmeter |
* Charge ammeter |
|
|
|
|
|
|